Search

PICV

PICV

The Pressure Independent Control Valves (PICVs), Model ICCB use dynamic-balancing to handle pressure fluctuations in a building’s hydronic heating or cooling system. Aside from achieving energy savings of up to 30% by controlling system underflows and overflows, PICVs drastically reduce temperature swings, helping to maintain occupant comfort. 
Our ICCB PICVs offer a ‘three-in-one’ solution, with volume flow control, differential pressure control, and two port control and actuation. With two operating modes, the valve can be used to restrict flow rate or entirely shut-off the fluid to automatically balance the system. Or alternatively, when connected to an actuator, the valve can be used to enable independent control of the pressure in accordance with the thermal load requirements of the circuit section. Conex Bänninger’s PICV allows for an 8 bar pressure differential to ensure the flow rate remains constant over a wider ΔP range than other PICVs available on the market.

Product Introduction

The Pressure Independent Control Valves (PICVs), Model ICCB use dynamic-balancing to handle pressure fluctuations in a building’s hydronic heating or cooling system. Aside from achieving energy savings of up to 30% by controlling system underflows and overflows, PICVs drastically reduce temperature swings, helping to maintain occupant comfort. 
Our ICCB PICVs offer a ‘three-in-one’ solution, with volume flow control, differential pressure control, and two port control and actuation. With two operating modes, the valve can be used to restrict flow rate or entirely shut-off the fluid to automatically balance the system. Or alternatively, when connected to an actuator, the valve can be used to enable independent control of the pressure in accordance with the thermal load requirements of the circuit section. Conex Bänninger’s PICV allows for an 8 bar pressure differential to ensure the flow rate remains constant over a wider ΔP range than other PICVs available on the market.


Benefits

Patented Double Scale H &L volume flow setting scale
Double Union Connections for ease of Maintenance
Simplified commissioning and setting
Quick & Easy Selection
Reduced Product Range due to dual operating range

Applications 

Fan coil systems (FCU)
Air handling unit systems  (AHU)
Low Temperature Hot Water Systems  (LTHW)

 

Operating Parameters 

 Temperature range: +5°C to 120°C
 Working differential pressure range: 25 to 800 kPa with  or without actuator

Operating Pressures 

Max. working pressure: 25 bar

Standards 

Valve performance tested  to the BTS 1/2019 testing standard.

Sizes

1/2", 3/4" and 1" BSP

Warranty 

When professionally installed, used and maintained in accordance with  installation instructions, 
Conex Universal Ltd. guarantees that PICV s supplied by Conex Universal Ltd. will be free of material defects resulting from errors in manufacture, for two (2) years from the date of first purchase by an end user.  For full terms and conditions please refer to the product warranty.

Details